1. Deflection
limit is taken as Span/200. FJI45/240 and lesser joists will
defect more
under maximum spans (from span
tables) with temporary load.
2. All timber must be kept dry when applying maximum
temporary loading.
3. Loads are to be spread equally over a minimum
of 2 joists using timber bearers at min
1200mm in length or a standard 1200 x
1200mm pallet.
4. No loads are to be stacked over any part of
the length of joists fixed to an opening header
or trimmer joist, such as stair
header or SVP trimmer.
5. Plasterboard on the underside is not in place
- for multi span beams the bottom flange
requires adequate temporary bracing.
Joists supported on
hangers may require propping. Please consult your hanger
supplier for details. For any other queries regarding FJI
Joists contact
Finnforest Technical Support on 01205 883 835